APPENDIX C
VENDOR SURVEY INSTRUMENT

This is a representation of the Vendor Survey that was used both as a telephone-survey guide and occasionally mailed or faxed to potential vendors of secondary treatment technologies. Contact was made with 38 separate firms (plus subsidiaries), 15 of which supplied useful information.

Vendor Information

Company Name

Sales Contact

Technical Contact

Telephone

E-mail Address

Fax

Mailing Address

Treatment Category (circle one)
  • UV Irradiation
  • Ultrasonic
  • Heat
  • Other ______________
Physical Operation Parameters

(convey these to vendor, edit if vendors system requires different specifications)

  • Flow rates:
  • 1,200 gpm (4,500 L/min)
    8,000 gpm (30,000 L/min)

  • Intake diameter: 8-inch (200mm), 20-inch (500mm)
  • Intake pressure: 70 psi
  • Intake temperature: 35-45EF (2-7EC)
  • Platform vibration and corrosion conditions typical of commercial ship equipment compartments
 Operational Requirements

(For physical operation parameters to left)

  • Power source and energy consumption at 1200 and 8000 gpm rates
  • Equipment weight and dimensions (incl. footprint), single or multiple units? Recirculation necessary?
  • O&M procedures (incl. cleaning solutions and potential chemical byproducts/discharges, hours of operation prior to necessary maintenance/recalibration)
  • Special Requirements (incl. operator training and safety issues: caustic corrosive substances)
  • Cost (for both equipment and maintenance)
  • Largest unit in current operation

 

APPENDIX C

VENDOR SURVEY INSTRUMENT
(continued)

This is a representation of the Vendor Survey that was used both as a telephone-survey guide and occasionally mailed or faxed to potential vendors of secondary treatment technologies. Contact was made with 38 separate firms (plus subsidiaries), 15 of which supplied useful information.

Performance (Biological Eradication) with

No Pretreatment Filtration

  • Estimated mortality to organism by type and size
  • Percent effectiveness of mortality to organism type and size
  • Anticipated changes in operational requirements as a result of this pretreatment
  • Unintended impacts/environmental concerns (e.g., potentially toxic byproducts, accelerated corrosion etc.)
Performance (Biological Eradication) with

250 m Pretreatment Filtration

  • Estimated mortality to organism by type and size
  • Percent effectiveness of mortality to organism type and size
  • Anticipated changes in operational requirements as a result of this pretreatment
  • Unintended impacts/environmental concerns (e.g., potentially toxic byproducts, accelerated corrosion etc.)
Performance (Biological Eradication) with

100 m Pretreatment Filtration

  • Estimated mortality to organism by type and size
  • Percent effectiveness of mortality to organism type and size
  • Anticipated changes in operational requirements as a result of this pretreatment
  • Unintended impacts/environmental concerns (e.g., potentially toxic byproducts, accelerated corrosion etc.)
Performance (Biological Eradication) with

25 m Pretreatment Filtration

  • Estimated mortality to organism by type and size
  • Percent effectiveness of mortality to organism type and size
  • Anticipated changes in operational requirements as a result of this pretreatment
  • Unintended impacts/environmental concerns (e.g., potentially toxic byproducts, accelerated corrosion etc.)
Supplemental Vendor/System Information
  • Literature requested _ YES _ NO
  • Availability of Vendor to provide experimental treatment systems _ YES _ NO
  • Other Contacts (e.g., trade association, researchers):
  • Related Technologies:
  • Other: